M-Series Cumulative Industrial Flow Meter

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (12)
  • M-Series Cumulative Industrial Flow Meter
  • M-Series Cumulative Industrial Flow Meter
  • M-Series Cumulative Industrial Flow Meter
  • M-Series Cumulative Industrial Flow Meter
  • M-Series Cumulative Industrial Flow Meter
  • M-Series Cumulative Industrial Flow Meter
Find Similar Products

Basic Info.

Accuracy
≤±0.1%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size
DN15----DN200
Sensor
Plug-in
Application
Environmental Protection
Type
Probe Type Flow Meter
Measuring Media
Solid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Transport Package
Woodec Box
Trademark
China Jitai
Origin
Zhejiang
Production Capacity
50000

Product Description

M-Series Cumulative Industrial Flow Meter
1.WORKING
  PRINCIPLE

1.0 WORKING PRINCIPLE FOR THE METERING BODY
2.MODELS
3.TYPICAL  APPLICATION 4.TECHNICAL DATA
5.INSTALL  REQUIREMENT
6.OPERATE  REQUIREMENTS 7.TROUBLESHOOTING
8.DIMENSION
8.1M-40  METER  DIMENSION 8.2 M-50 METER DIMENSION
8.3 M-80 METER DIMENSION
8.4 M-100 METER DIMENSION

8.5M-150  METER  DIMENSION 9.0 SPARE PARTS
9.1 METER
9.1.AEXPLOSION  DRAWINGS OF METER
9.1.B SPARE PARTLISTS OF METER
9.2 FILTER
9.2.AEXPLOSION  DRAWINGS OF FILTER
9.2.B SPARE PART LISTS OF FILTER
9.3 AIR ELIMINATOR


1.Working         principle

1.0 Working principle for the metering body

M series  meter  is  positive  displacement  meter  for  liquids.They  are  designed  for  liquid metering both in transfer and process control applications.Thanks to their design they are easy to keep and can suit a wide range of applications.The meter consists of a housing where two bladed  displacement  rotors  and  a  central  single  blocking  rotor  turn  in  synchronized relationship within three cylindrical bores with no metal-to-metal contact within the meter element.Each rotor is supported on either end by a bearing plate through which the rotor shafts protrude.

The bladed displacement rotors,alternately move through the two half-cylinder bores of the meter element,while the single blocking rotor rotates within its bore in such a way as to produce a continuous capillary seal between the unmetered upstream product and the metered, downstream product.

At one end of each rotor shaft is a timing gear.The blocking rotor gear,having twice the number  of teeth  of each  of the  displacement  rotor  gears,rotates  at  half the  RPM  of the displacement rotors.
M-Series Cumulative Industrial Flow Meter
3.0 Typical Application:


  Check   of  loading/unloading   operations   of   fuel   and   petrochemical   products   in   fuel   bulk plants  and/or  refineries
On truck tanker for fuel/LPG transport and delivery
 Heavy  duty  fuel  dispensing  system  for  big  vehicles  and  airplanes

Typical  Application  of  Aluminum  Construction

Class   1   meter:refined   petroleum    products,such   as    gasoline,fuel   oil,diesel    fuel,kerosene, ethylene  glycol,motor  oils  and  rotogravure  ink.
Class 2 meter:aviation gasoline and jet fuels.

Class  3  meter:a  wide  variety  of  products   such  as:liquid  sugars,corn  syrup,corn  sweetners,
dextrose,fructose,sucrose,maltose,lactose,corn    oil,soy     bean     oil,cotton     seed     oil,coconut     oil,
 

and shortening's etc.rate of flow is based on viscosity to pressure loss relationship.
Class  10  meter:liquefied  petroleum  gas(LPG)including  butane,isobutene,pentane,ethane, freons and propane.
Class 14 meter:crude oil,also for heated and/or viscous liquids including animals fats,resins, #6 oil and non-abrasive asphalt emulsions.

Class 15 meter:for metering oil or water based latex products,polyester resins,and adhesives (neutral pH).also available for metering herbicides and nitrogen fertilizer solutions (requires   Vito n and Teflo seals).

Class  16  meter:for general solvent metering,such as methanol,toluene,xylene,naphtha, acetone,MEK,MIBK,and  alcohols  including  ethanol.


4.0 Technical data

Flow    rate:M-40     1-1/2"25L-250L/min
M-50           2"38L/min-550L/min
M-80     3"75L/min-1150L/min   M-100    4"130L/min-1700L/min M-150    6"300L/min-3000L/min
Max   Pressure:10Bar/150PSI
Standard measure unit:Liter and US Gallon for option Repeatability:0.05%
Type  of  flange:ANSI,NPT,BSPF
Strainer mesh:80Mesh for diesel,40Mesh for gasoline.

5.0 Installation requirement
 Make  sure  you  observed  all  of  safety  rules  concerning  room  ventilation,temperature control,fire prevention and fire extinguishing systems
 Make  all  connections  in  order  to  ensure  the  meter  and  grounding  device  system  are equipotential.
 Make sure you can get easily to fire extinguishers for your product.Consult your local fire   department   for   proper   information   about   fire   problems   and   mandatory   law dispositions
  Install the meter and its accessories complying with the electric and safety standards in force.
 Prior to meter installation the entire piping system must be flushed,with a liquid that is compatible with the construction ofthe meter
 Keep the meter external surfaces clean in order to notice easily possible defects
 The  meter  must  be  firmly  fastened  to  a  platform  or  other  support  regardless  or  its mounting position.Never hand the meter to the piping system and do all necessary to
 

avoid that piping tensions due to such cases as material dilation by temperature,stress of flange screw,etc.Are conveyed to the meter assembly.Expansion joints both at the inlet and outlet of the meter assembly will prevent it from these tensions
  Calculate  suitable  working   areas  for  maintenance   operations.Remember  you   need  a support where to mount the meter
 Meters are designed with special materials depending on the liquid/s they are used.Their compatibility  with  a  certain  class  of  liquids  is  indicated  on  the  M  series  tag.Meters should not be used with  other  liquids.In  case  of doubt  please  apply  to  M  series  for information
 If required,convey the piping downstream of the meter towards a bank prover in order to carry out calibration and/or metrological check
 When missing in the assembly install a  suitable  strainer upstream of the meter so as to strain every foreign material (welding dross,dirt etc.)Foreign bodies over a certain size could get into the rotors and cause them to seize.
 When the meter assembly has got an air eliminator you have to connect the two outlet threaded ports (or just one when the assembly includes an air check valve)to the tank of the liquid which is metered or to other sealed container under ambient pressure.This to  avoid contamination of the surrounding
 There  is  a  mutual  relationship  between the  liquid  flow  direction  in  the  meter  and  the correct  indication  of  the  delivered  quantity  on  the  register  display;if  you  desire  the register to count down you will have to reverse the position of the adjuster drive gear.
 New or repaired piping can be the source of welding dross or foreign material which clog or break the strainer network.The strainer basket must be daily checked during the first 100hours of operation
 A  frequent  check  and  cleaning  of  the   strainer  are  required  in  order  to  get  a  good performance.Locate the strainer on the inlet side of the meter.Screw the strainer firmly to the meter flange.Fasten the piping to the strainer
 The  meter  and  its  accessories  must  not  support  the  weight  of piping  system.There  is enough room to remove the air eliminator
 Locate the air eliminator on the inlet side of the meter.Always mount the air eliminator in vertical position.Screw the air eliminator to the coupling flange of the strainer.Connect and fasten the piping to the air eliminator



6.0 Operation requirements
  The meter must remain full of product at all times.An easy way to accomplish this is to put the meter  assembly  in the  line below  the piping  centre-line.This requires  adding elbows and flanges prior to installing the meter.The meter should be installed in a bypass loop,below  the  pipe  centre-line,with  block  valves  upstream  and  downstream.A  block valve  should  be  located  in  the  mainstream,labeled  as  the  bypass  valve.Mounting  the meter like this allows to keep the meter always full of liquid and to isolate it for servicing or calibration when required,while continuing flow through the bypass-valve.
 

Attention:every  part  of  the  piping  which  could  stop  and/or  isolate  the  flow  should  be provided with a pressure relief to prevent damages from thermal expansion.
 Upstream  lines  must  be  maintained  full  to  prevent  air  from  entering  the  meter.If  the upstream or inlet lines are constructed in a manner which allows reverse flow,foot valves or back checks must be installed
 Underground  tanks  that  are  furnished  with  a  submersible  pump  will  eliminate  many problems  that  occur  with  positive  displacement  pumps(suction  pumps)when  suction piping is incorrectly sized ofwhen the lift is too great.
 Give careful attention to your system's pumping equipment and piping because of their influence on liquid being measured as it enters the meter assembly.Systems should be made free of conditions that cause or introduce entrained air or vapor
 Follow the manufacturer's recommendation  fully when  installing pumps.Give particular attention to factors like:use of foot valve,pipe size to the inlet and conformance to net positive suction head conditions when suction pumping is required.
 For volatile liquids,such as light hydrocarbons which tend to flash or vaporize easily at higher ambient temperatures,it is desirable to use flooded suctions and piping sized large than the normal pump size
 When locating the meter under a tank (on truck tankers)the course of the suction piping affects  metering  precision.The  piping  should  have  a  constant  inclination  towards  the pump avoid goosenecks
 Hydraulic shock is harmful to all components of an operating system including valves, pump and the meter.In particular meters must be afforded protection from shock because of their need to measure with high precision.Generally the best protection is prevention, which can be readily accomplished by adjusting valve closing rates in such a manner that shock does not occur.
 Thermal expansion like hydraulic shock is a phenomenon that can easily damage meters and systems in general.Care should be taken in designing the system to include pressure relief valves in any portion or branch of the system that might be closed off by closure of operating valve or block valves
 The meter can operate in a dry condition(with no liquid)for no longer than 5 minutes
  The meter shall operate within the recommend flow rate range.Only in some exceptional events it may be allowed to let it work with a 20%higher flow rate than the nominal one and only for a short time.
 Start up during the starting up the system shall be slowly filled in with liquid.There shall be no air in this phase.Take care not to damage the meter.The system should be filled in by gravity or by using a pump
  Filling  in  the  system  by  means  of  a   pump.Apply  to  the  pump  manufacturer  for information  about  its  loading.After  the  pump  has  been  loaded  with  liquid,operate  as follows:
Make sure the downstream valve is shut down The meter counter will start turning
When the meter has started counting volume open completely the valve
In this phase the meter should not run faster than 20%of its rated flow.Once the product is flowing out the end of your system,the outlet valve can be opened all the way provided
 

that the system is designed not to exceed the flow rate marked on the meter
 Never  use  the  meter  or  the  system when they  are not completely  full of liquid or in presence  of air  bubbles  or  compressed  air/vapour.If  this  is  not  possible  you  require devices to eliminate air/vapour.

7.0 Troubleshooting

 
ITEM TROUBLE CAUSE    AND    SOLUTION
1 Leakage from the lid seal The seal has been damaged by pressure or bolts have been screwed incorrectly
2 The product flows through the  meter but is not counted by the register A.Check the packing glands and gears
B.If all parts work properly the problem is to be found in the register which is detective and  should be checked and repaired
3 Gear cogs are broken Sharp flow variations
4 The product flows through the  meter but the register does not work correctly A.The register has not been adjusted correctly
B.Wrong gear plate ratio or wrong installation of a gear on the plane
5 The meter operates slowly The internal valve gear is detective.The valve doesn't open correctly
6 The blocking and displacement rotors do not turn A.Breaking of the strainer basket likely due to unproper maintenance.Replace the strainer
basket and follow maintenance procedures. Clean out the meter and its parts
B.The basket got dented so as to cause leaks
which allow the intrusion of strange bodies. Replace the basket
C.Blocking and displacement rotor are blocked. Call the service company.
7 Leak  of  product  from  the
strainer lid
A.the trouble may be due to seals which are
damaged or worn out.Replace the seals.If they are Teflo  made replace them even if still in a good condition.
B.Dirty surfaces which prevent a perfect sealing  by the gaskets.Clean out the gaskets housings.
8 Pressure drop in the strainer or flow decrease in the meter A.the basket network is clogged by intruded
material.Clean out the strainer body and basket
B.the basket network size does not fit the liquid viscosity.Replace the basket with a new one  having a proper net size (thicker or looser,with more or less"meshes")
9 The floater in the air eliminator is crushed The crushing is due to water hammers,the floater is always in the position of open slots,letting the
 
    liquid leak from them or in the position of closed slots,letting air and vapour go through the meter. Beware water hammers and replace the floater
10 The floater in the air eliminator is punctured As time goes by the floater can get punctured and
fill with product when operating,so that it gets
heavy and remains in the position of open slots.
This causes the product to leak from the slots.
Replace the floater
11 The reeds in the air eliminator are worn out There is not a perfect sealing with the slots.This cause the product to leak.Replace the reeds.
12 The product leaks from the air eliminator lids The gaskets or the rubber coated plates are worn out.Replace the plates or the gaskets.

8.0 DimensionsM-Series Cumulative Industrial Flow Meter
9.1.B Spare Part Lists of Meter
 
  M-40 M-50 M-80 M-100 M-150
Q.ty Description Class 1 Class 2 Class 1 Class 2 Classl Class2 Class 1 Class 2 Class 1 Class 2
1 Houshing 0101-01011   0101-02011   0101-03011   0101-04011   0101-05011  
2 O-ring 0102-01011   0102-02011   0102-03011   0102-04011   0102-05011  
2 Displacement Rotor Assy 0103-01011   0103-02011   0103-03011   0103-04011   0103-05011  
2 Plate Bearing 0104-01011   0104-02011   0104-03011   0104-04011   0104-05011  
2 Gear displacement Pinion 0105-01011   0105-02011   0105-03011   0105-04011   0105-05011  
2 Washer Rotor Gear 0106-01011   0106-02011   0106-03011   0106-04011   0106-05011  
2 Screw 0107-01011   0107-02011   0107-03011   0107-04011   0107-05011  
1 Front Cover 0108-01011   0108-02011   0108-03011   0108-04011   0108-05011  
2 Plug 0109-01011   0109-02011   0109-03011   0109-04011   0109-05011  
5 Flat Washer 0110-01011   0110-02011   0110-03011   0110-04011   0110-05011  
4 Screw 0111-01011   0111-02011   0111-03011   0111-04011   0111-05011  
1 Packing Gland Assy 0112-01011   0112-02011   0112-03011   0112-04011   0112-05011  
1 Gear Packing Gland 0113-01011   0113-02011   0113-03011   0113-04011   0113-05011  
1 Drive shaft Bushing 0114-01011   0114-02011   0114-03011   0114-04011   0114-05011  
1 Retainer Bearing 0115-01011   0115-02011   0115-03011   0115-04011   0115-05011  
2 Screw 0116-01011   0116-02011   0116-03011   0116-04011   0116-05011  
1 Screw 0117-01011   0117-02011   0117-03011   0117-04011   0117-05011  
1 Plate Dust Cover 0118-01011   0118-02011   0118-03011   0118-04011   0118-05011  
1 Retaining Ring 0119-01011   0119-02011   0119-03011   0119-04011   0119-05011  
1 Pinion Gear 0120-01011   0120-02011   0120-03011   0120-04011   0120-05011  
1 Shaft 0121-01011   0121-01011   0121-01011   0121-04011   0121-05011  
  Bracket Counter 0122-01011   0122-01011   0122-01011   --   0122-05011  













 
3 Screw 0123-01011   0123-02011   0123-03011   0123-04011   0123-05011  
1 Adjuster Assy 0124-01011   0124-01011   0124-01011   0124-04011   0124-05011  
1 Screw 0125-01011   0125-02011   0125-03011   0125-04011   0125-05011  
1 Washer,lock 0126-01011   0126-02011   0126-03011   0126-04011   0126-05011  
1 Driver Packing Gland 0127-01011   0127-02011   0127-02011   0127-04011   0127-05011  
1 Gear Blocking Rotor 0128-01011   0128-02011   0128-03011   0128-04011   0128-05011  
8 Screw 0129-01011   0129-02011   0129-03011   0129-04011   0129-05011  
3 Key Stainless Steel 0130-01011   0130-02011   0130-03011   0130-04011   0130-05011  
1 Blocking Rotor Assy 0131-01011   0131-02011   0131-03011   0131-04011   0131-05011  
4 Pin Dowel 0132-01011   0132-02011   0132-03011   0132-04011   0132-05011  
1 Screw 0133-01011   0133-02011   0133-03011   0133-04011   0133-05011  
20 Cover Rear 0134-01011   0134-02011   0134-03011   0134-04011   0134-05011  

9.2 Filter

9.2.A Explosion Drawings ofFilterM-Series Cumulative Industrial Flow Meter
9.2.B Spare Part Lists of Filter
 
    GLQ-50 QLQ-80 QLQ-100
Q.ty Description Class 1 Class 2 Class 10 Class 1 Class 2 Class 10 Class 1 Class 2 Class 10
12 Screw 0201-01011     0201-02011     0201-03011    





 
12 Washer 0202-01011     0202-02011     0202-03011    
1 Flange 0203-01011     0203-02011     0203-03011    
1 Flange Gasket 0204-01011     0204-02011     0204-03011    
8 Screw 0205-01011     0205-02011     0205-03011    
8 Washer 0206-01011     0206-02011     0206-03011    
1 Cover 0207-01011     0207-02011     0207-03011    
1 0-ring 0208-01011     0208-02011     0208-03011    
1 Housing 0209-01011     0209-02011     0209-03011    
1 Gasket 0210-01011     0210-02011     0210-03011    
1 Strainer 0211-01011     0211-02011     0211-03011    
1 Cover 0212-01011     0212-02011     0212-03011    

9.3 Air Eliminator
9.3.A Spare Part Lists of Air Eliminator
 
Q.ty Description Class 1/16 Class 2 Class 7 Class 8 Class 17
1 Cup,Baffle 0506-01011        
1 Housing 0501-01011        
1 Float and Stop 0505-01011        
2 Screw 0507-01011        
2 Valve Reed 0502-01011        
2 Cover,Air elimination 0508-01011        
1 Valve Plate Assy 0503-01011        
1 Plug 0109-01011        
1 Valve Plate ltd bleed 0510-01011        
2 Seal ring,Outlet 0509-01011        
12 Screw 0504-01011        

M-Series Cumulative Industrial Flow MeterM-Series Cumulative Industrial Flow MeterM-Series Cumulative Industrial Flow MeterM-Series Cumulative Industrial Flow MeterM-Series Cumulative Industrial Flow MeterM-Series Cumulative Industrial Flow Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier