Aluminum Alloy Natural Gas Solenoid Valve

Product Details
Media: Gas
Temperature: High Temperature
Actuator: Electric
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (12)
  • Aluminum Alloy Natural Gas Solenoid Valve
  • Aluminum Alloy Natural Gas Solenoid Valve
  • Aluminum Alloy Natural Gas Solenoid Valve
  • Aluminum Alloy Natural Gas Solenoid Valve
  • Aluminum Alloy Natural Gas Solenoid Valve
  • Aluminum Alloy Natural Gas Solenoid Valve
Find Similar Products

Basic Info.

Model NO.
ZCM
Connection Form
Thread
Type
Direct Acting
Material
Brass
Pressure
Ordinary Pressure
Valve Structure
Direct-Acting Piston Structure
Power Supply
AC Solenoid Valve
Usage
Safety, Emptying, Drain, Temperature Control, Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Household Usage
Transport Package
Cartons
Production Capacity
50000

Product Description

Product Description

12V Electromagnetic Brass Copper Aluminium Solenoid Valve for Gas Emergency Cut off (ES-610GV)

Main Features
  • Suitable gas:natural gas; Liquefied petroleum gas;
  • Artificial coal gas, etc. Non corrosive gas            
  • Way of closing valve:DC pulse drive / manual   
  • driving voltage: DC9V~DC12V.(pulse)
  •  body material:Copper alloy                        
  • Driving current: <2A(pulse)  
  • Sealing material:NBRrubber                        
  • Valve closing time:Less than 1 second  
  • Working environment temperature:-10ºC~+50ºC     
  • Explosion proof type:Exmb II C T4 Gb  
  • Maximum working pressure:100kPa                  
  • Outlet length: 0.4CM  
  • Connection mode:G1/2"(DN15A)/G3/4"(DN20A) /G1"(DN25A)      
  • Open valve mode:Manual reset                            
  • Implementation standards:GB3836.9  
Operation instructions

1. Valve in the open state there are two ways to close the valve:
To provide a solenoid coil(About 1 second)Instantaneous direct current pulse(DC 9~12V)

electric energy,Valve is quickly closed;      

Open the protective cover,Hand press down the red handle can also be turned off valve. Off valve after the state self maintained.

be careful:Normally it is not suitable to open the protective cover,So as to avoid the wrong operation off valve.

2. There is only one way to open the valve when the valve is closed.:Pull the red handle manually,Open valve. Open valve state can be maintained.
be careful:Open valve,As the handle to lift the trouble,Measures should be taken to make both ends of the valve inlet and outlet pressure balance,Balance valve open.
Avoid barbaric operation,In order to avoid damage to the valve actuator.

3. Valve in the open state:Due to the principle of magnetic lock design,Therefore, when the valve in the event of a strong shock,Valve may be automatically closed,
Under normal conditions. If the open valve self locking force is not normal(Too small),Manufacturers should be notified maintenance.

4. When the valve is cut off,Must be confirmed on the spot,To eliminate the hidden trouble of the accident can be manually reset,Recovery ventilation.

Installation requirements         

1. Valve installation unit should have the corresponding qualification and according to the relevant gas pipeline construction standard installation.
2. The valve should be installed in the general indoor air inlet valve,In order to repair.
3. Should be installed in accordance with the direction of flow valve body,Body coil not inverted,Allows horizontal and vertical installation.
4. Solenoid valve control line should be correct and reliable connection,Control line polarity:The white line is positive,Black line is negative,Can not answer.
5. Pipe purge,The proposal to isolate the solenoid valve,In order to avoid damage to the valve sealing material.
6. Pipeline in the test of pressure test before sealing performance,Should first open the valve state of the solenoid valve.
7. Manual valve opening,Should be in the valve inlet and outlet pressure balance operation.
8. Electric off valve,Don't take the wrong power,Such as: the wrong polarity, plus the wrong voltage or a long time power, etc.,So as not to damage the electromagnetic coil. 

 Exterior dimension

Aluminum Alloy Natural Gas Solenoid Valve
Specifications A(mm) B(mm) C(mm) D(mm)
DN15 63 30 91 105
DN20   74   37   95 112
DN25 78   40   96 116