Rapid Electric Ball Valve
Automatic reset: Open/Close Switching speed: 1 second/3 seconds
Operating voltage: AC/DC 6V/12V/24V/36V/220V
Operating medium: Water (high-temperature steam not applicable), liquids, gases, light oils, etc.
Medium temperature: -5- 120°C Operating pressure: -0.1-1.0 MPa
Valve body material: 304 G thread
Connection method: 1. G thread 2. Quick-connect 3. Flange
Port size: DN15-DN50
Features: Zero leakage, full bore, high vacuum, high flow rate, no distinction between inlet and outlet, and no distinction between flow direction. Durable, automatic power-off protection when the switch is in the correct position, and the medium allows small particles. Energy-saving, stable operation.
Wiring: 1. Two-wire wiring without distinguishing between live and neutral wires, just connect to the appropriate power supply 2. Three-wire wiring with two-way control
Warranty period: 1 year, waterproof IP67 installation position: 360-degree no dead angle, can be installed horizontally, vertically, or upside down. Precautions
1. Fast electric ball valve, two-wire automatic reset ball valve needs to be powered on for at least 15 seconds every time it is used, otherwise there may be a problem of insufficient charging that the valve may not close properly. If the working conditions are not suitable, a three-wire two-control ball valve can be used.
2. Confirm the voltage of the power supply before installation.
3. After the wiring connection is made, confirm that the connection will not loosen due to vibration and cause the electric valve not to work.
4. The pipeline should be secure, pipeline vibration will affect the service life of the electric valve.
5. Do not disassemble or modify the circuit without permission from our factory, otherwise we will not be able to provide normal after-sales service.
6. This product is not explosion-proof and cannot be used in scenarios with explosive gases and flammable and explosive substances.
7. For places where the product failure may cause major personnel casualties or property losses, please use with caution and prepare corresponding contingency plans and spare parts.